TM-9-2320-366-34-1 MTV Direct Maintenance Manual M1083 Series - Volume 1 Download
Page 1220 of 1591
TM 9-2320-366-34-1 TM 9-2320-366-34-1 TM 9-2320-366-34-1 TM 9-2320-366-34-1 TM 9-2320-366-34-1  MONOBLOCK VALVE FLOW TEST  WARNING  Wear approved eye protection when performing  pressure checks. Failure to comply may result  in oil getting into eyes. If oil contacts eyes, seek  medical attention immediately.  Drop hydraulic pressure to zero before  disconnecting any hydraulic hose, tube, or fitting.  Failure to comply may result in injury to personnel.  Fuel and oil are slippery and can cause falls.  Wipe up spilled fuel or oil with rags. Failure  to comply may result in injury to personnel.  Tag hydraulic hoses, tubes, and fittings  prior to disconnecting.  NOTE  (1) Place drain pan under vehicle.  (2) Disconnect hydraulic hose from input of  monoblock valve assembly control valve.  (3) Connect hydraulic tester between hose and  fitting with hoses and adapters.  (4) Start engine (TM 9-2320-366-10).  (5) Position PTO switch to ON (TM  9-2320-366-10).  (6) Observe flow of 12-14 gpm (45-53 lpm)  at 2400-2950 psi (16548-20340 kPa).  (7) If flow and pressure are not between  12-14 gpm (45-53 lpm) and 2400-2950  psi (16548-20340 kPa), replace  hydraulic rotary pump (para 16-91).  (8) Position PTO switch to OFF (TM 9-  2320-366-10  (9) Shutdown engine (TM 9-2320-366-10).  (10) Disconnect flow/pressure kit and  disassemble test equipment fittings  and hoses from pressure flow kit,  (11) Connect main valve tube to fitting.  (12) Remove drain pan.  2-1063 2-1063 2-1063 2-1063 2-1063