TM 9-2320-366-34-1 TM 9-2320-366-34-1 TM 9-2320-366-34-1 TM 9-2320-366-34-1 TM 9-2320-366-34-1 KNOWN INFO TEST OPTIONS 1. START NO YES Control Valve Flow Test REASON FOR QUESTION WARNING Read WARNING on following page. Replace eight bank valve assembly (para 16-59). Is flow and pressure through boom telescope control valve OK? Hydraulic oil level OK. PTO OK. Hydraulic hoses, tubes and fittings OK. Hydraulic pump OK. Monoblock valve OK. Tele-out lockout solenoid. POSSIBLE PROBLEMS Faulty control valve. Faulty holding relief valve. Faulty boom lift cylinder. Faulty control valve will cause boom to not telescope. j7. M1089 MATERIAL HANDLING CRANE (MHC) BOOM DOES NOT TELESCOPE IN OR OUT INITIAL SETUP Equipment Conditions Engine shut down (TM 9-2320-366-10-1). Personnel Required (2) Tools and Special Tools Tool Kit, Genl Mech (Item 78, Appendix B) Tester, Hydraulic (Item 73, Appendix B) Pan, Drain (Item 43, Appendix B) Goggles, Industrial (Item 28, Appendix B) Materials/Parts Rag, Wiping (Item 60, Appendix C) Hose (2) (Item 40, Appendix C) Fitting (2) (Item 31, Appendix C) Reducer, Tube (Item 61, Appendix C) Adapter, Swivel (Item 3, Appendix C) Adapter, Pipe (Item 2, Appendix C) Fitting (Item 32, Appendix C) Adapter, Pipe (Item 1, Appendix C) 2-1056 2-1056 2-1056 2-1056 2-1056