TM-9-2320-366-34-1 MTV Direct Maintenance Manual M1083 Series - Volume 1 Download

Page 1177 of 1591

TM 9-2320-366-34-1 TM 9-2320-366-34-1 TM 9-2320-366-34-1 TM 9-2320-366-34-1 TM 9-2320-366-34-1 2. REASON FOR QUESTION TEST OPTIONS NO YES Flow and Pressure Test Go to step 4 of this fault. KNOWN INFO POSSIBLE PROBLEMS CAUTION Read WARNING and CAUTION on following page. WARNING Hydraulic oil level OK. Hydraulic hoses, tubes, and fittings OK. 15K self-recovery winch electric circuit OK. Hydraulic oil tank, filters, and strainers OK. 15K self-recovery winch control valve assembly OK. Faulty 15K self-recovery winch counterbalance valve. Faulty 15K self-recovery cartridge valve. Faulty 15K self-recovery hydraulic motor. Faulty 15K self-recovery winch. Faulty hydraulic rotary pump. Is there 15-18 GPM (57-70 lpm) at 2450- 2,600 psi (16893-17,927 kPa) measured at output of hydraulic rotary pump? Replace hydraulic rotary pump (para 16-91). If hydraulic rotary pump flow and pressure is not correct, hydraulic rotary pump is faulty. i1. 15K SELF-RECOVERY WINCH DOES NOT WORK (CONT) i1. 15K SELF-RECOVERY WINCH DOES NOT WORK (CONT) i1. 15K SELF-RECOVERY WINCH DOES NOT WORK (CONT) i1. 15K SELF-RECOVERY WINCH DOES NOT WORK (CONT) i1. 15K SELF-RECOVERY WINCH DOES NOT WORK (CONT) 2-1020 2-1020 2-1020 2-1020 2-1020