TM 9-2320-366-34-1 TM 9-2320-366-34-1 TM 9-2320-366-34-1 TM 9-2320-366-34-1 TM 9-2320-366-34-1 2-966 2-966 2-966 2-966 2-966 Hydraulic oil level OK. Hydraulic tubing and fittings OK. Filter screen OK. Hydraulic filter OK. 1. YES START NO KNOWN INFO POSSIBLE PROBLEMS WARNING Read WARNING on following page. TEST OPTIONS Visual inspection REASON FOR QUESTION Tools and Special Tools Tool Kit, Genl Mech (Item 78, Appendix B) Tester, Hydraulic (Item 73, Appendix B) Goggles, Industrial (Item 28, Appendix B) Pan, Drain (Item 43, Appendix B) e1. LOSS OF HYDRAULIC PRESSURE Faulty rotatry hydraulic pump. If hydraulic rotary pump is overheating while operating this indicates that there is internal damage. Replace hydraulic rotary pump (para 16-91). Is hydraulic rotary pump cool enough to touch while operating? INITIAL SETUP Equipment Conditions Engine shut down (TM 9-2320-366-10-1). Personel Required (2) Materials/Parts Rag, Wiping (Item 60, Appendix C) Hose (2) (Item 40, Appendix C) Fitting (2) (Item 31, Appendix C) Adapter, Pipe (Item 1, Appendix C)