Change 1 2-867  TM 9-2320-366-34-1  CONTINUITY TEST  (1) Set multimeter to ohms.  (2) Connect positive (+) probe of multimeter  to connector P119-A.  (3) Connect negative (-) probe of multimeter  to connector P67-f and note reading on  multimeter.  (4) If continuity is not present, replace  transmission external wiring harness  (para 6-7).  (5) Connect positive (+) probe of multimeter  to connector P119-A.  (6) Connect negative (-) probe of multimeter  to all other pins in connector P119 and  note reading on multimeter.  (7) Connect negative (-) probe of multimeter  to ground and note reading on multimeter.  (8) If continuity is present, transmission  external cable assembly is shorted; replace  transmission external wiring harness  (para 6-7).  (9) Connect connector P119 to connector  J119.  (10) Position front grille on cab with washer  and screw.  (11) Position two washers and screws in front  grille.  (12) Tighten screw to 48-60 lb-in. (5-7 N·m).  (13) Tighten two screws to 24 lb-in. (3 N·m).