TM 9-2320-366-20-5  23-11. AIR DRYER REPLACEMENT/REPAIR (CONT)  CAUTION  Use caution when installing desiccant  canister in inner aluminum shell. Preformed  packing can easily be damaged. Failure to  comply may result in damage to equipment.  (18) Install desiccant canister (14) in inner aluminum shell  (20).  (19) Install preformed packings (21, 22 and 23) on top cover  (24).  (20) Position spring (25) and top cover (24) on air dryer  housing (26) with matchmarks aligned.  (21) Position six flange nuts (27) on top cover (24).  (22) Tighten six flange nuts (27) to 150-200 lb-in. (17-23  N·m).  23-44