TM 9-2320-366-20-5 Figure 23-5. 30K Winch Air Hose Locations Table 23-5. 30K Winch Air Hose Locations HOSE NAME FROM TO Air supply Tank pressure valve fitting (1) Tee fitting (2) Manifold supply Tee fitting (2) Manifold input fitting (3) LH free spool Manifold output fitting (4) LH free spool input fitting (5) RH free spool Manifold output fitting (6) RH free spool input fitting (7) Change 1 23-15