TM-9-2320-366-20-5 MTV Unit Maintenance Manual M1083 Series - Volume 5 Download
Page 827 of 1158
TM 9-2320-366-20-5 Figure 23-1. Primary Air Supply Hose Locations Table 23-1. Primary Air Supply Hose Locations HOSE NAME FROM TO Primary supply Air compressor output fitting (1) Bulkhead fitting (2) Primary supply tie Bulkhead fitting (2) Air dryer input fitting (3) Wet tank supply Air dryer output fitting (4) Wet tank supply fitting (5) Primary tank supply Wet tank supply fitting (5) Primary tank supply fitting (6) Secondary tank supply Primary tank supply fitting (6) Secondary tank supply fitting (7) Air dryer pressure Air dryer bottom fitting (8) Hose fitting (9) Air compressor intake hose Intake air cleaner (10) Air compressor (11) Change 1 23-3