TM 9-2320-366-20-5 20-516 Change 2 20-80. DIGITIZATION KIT CIRCUIT BREAKER REPLACEMENT (CONT) b. Installation (1) Install circuit breaker (1) on power distribution panel PD1 (2). (2) Position electrical distribution block cover (3) on power distribution shelf (4). (3) Tighten wing screw (5) on electrical distribution block cover (3). (4) Install wing screw (6) in power distribution shelf (4). c. Follow-on Maintenance Connect batteries (para 7-57) End of Task NOTE Refer to Figure 3-1. Power distribution Circuit Breaker Locations and Table 3-1 Power Distribution Circuit Breakers for details.