TM 9-2320-366-20-5 20-76. M1085 TANK AND PUMP UNIT TIEDOWN KIT INSTALLATION/REMOVAL (CONT) NOTE Four adjustable safety hooks are installed the same way. One adjustable safety hook shown. (24) Position nut (33), lockwasher (34), and washer (35), on threaded rod (20). (25) Position threaded rod (20) in tiedown post (26) with washer (36), lockwasher (37), and nut (38). (26) Position safety hook (18) on lower tiedown ring (39). (27) Perform steps (24) through (26) on remaining safety hooks. (28) Tighten four nuts (33 and 38) to 75 lb-ft (102 N·m). NOTE Left and right middle chains are installed the same way. Left middle chains shown. (29) Install shackle (2) on lower tiedown ring (40) on tank (28) with pin (41) and cotter pin (42). 20-448