TM-9-2320-366-20-5 MTV Unit Maintenance Manual M1083 Series - Volume 5 Download
Page 602 of 1158
TM 9-2320-366-20-5 20-70. TROOP TRANSPORT ALARM SWITCH, CONNECTOR, AND BRACKET REPLACEMENT (CONT) WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (8) Apply sealing compound to threads of two knobs (14). (9) Install two knobs (14) on bracket (1). (10) Install two mounts (15) on knobs (14). (11) Remove bracket (1) from vise. (12) Install bracket (1) on cargo bed (16) with two knobs (11). (13) Connect connector P921 (17) to connector J921 (3). c. Follow-On Maintenance. Operate troop transport alarm and check for proper operation (TM 9-2320-366-10-1). End of Task. 20-386