TM 9-2320-366-20-5 20-57. 200 AMP TERMINAL BLOCK TO POWER DISTRIBUTION PANEL (PDP) 24 VDC CABLE REPLACEMENT This task covers: a. Removal b. Installation c. Follow-On Maintenance INITIAL SETUP Equipment Conditions Batteries disconnected (para 7-57). PDP cover removed (para 16-2). Spare tire lowered (TM 9-2320-366-10-2). Bottom radiator fan shroud removed (para 6-4). Tools and Special Tools Tool Kit, Genl Mech (Item 46, Appendix C) Wrench, Torque, 0-175 lb-ft (Item 58, Appendix C) Wrench, Torque, 0-200 lb-in. (Item 59, Appendix C) Socket Set, Socket Wrench (Item 34, Appendix C) Materials/Parts Ties, Cable, Plastic (Item 69, Appendix D) Lockwasher (Item 84, Appendix G) Lockwasher (Item 96, Appendix G) Nut, Self-Locking (2) (Item 153, Appendix G) a. Removal. (1) Remove three screws (1) and washers (2) from PDP (3). (2) Remove three screws (4) from PDP (3). (3) Lift PDP (3) outward to gain access. NOTE Remove plastic cable ties as required. (4) Remove screw (5), lockwasher (6), terminal lug TL42 (7), and four terminal lugs (8) from PDP (3). Discard lockwasher. (5) Position four terminal lugs (8) on PDP (3) with screw (5). 20-313