TM-9-2320-366-20-5 MTV Unit Maintenance Manual M1083 Series - Volume 5 Download

Page 524 of 1158

TM 9-2320-366-20-5 20-55. 200 AMP TERMINAL BLOCK TO REVERSE POLARITY RELAY 12 VDC BATTERY CABLE REPLACEMENT (CONT) NOTE Install plastic cable ties as required. (4) Install convoluted tubing (8) on 200 amp terminal block to reverse polarity relay 12 vdc battery cable (1) and 200 amp terminal block to reverse polarity relay 12 vdc load cable (9). (5) Install dust boot (10) on 200 amp terminal block to reverse polarity relay 12 vdc battery cable (1). (6) Position terminal lug TL173 (11) on reverse polarity relay 12 VDC BAT terminal (12) with lockwasher (13), and nut (14). (7) Tighten nut (14) to 120 lb-in. (14 N·m). (8) Position dust boot (10) on terminal lug TL173 (11). (9) Position turbocharger intake hose (15) on intake air cleaner boot (16) with clamp (17). (10) Tighten clamp (17) to 36-48 lb-in. (4-5 N·m). c. Follow-On Maintenance. (1) Connect batteries (para 7-57). (2) Raise spare tire (TM 9-2320-366-10-2). (3) Start engine (TM 9-2320-366-10-1). (4) Check VOLTS gage for charge indication (TM 9-2320- 366-10-1). (5) Shut down engine (TM 9-2320-366-10-1). End of Task. 20-308