TM 9-2320-366-20-5 20-51. 200 AMP TERMINAL BLOCK TO REVERSE POLARITY RELAY 24 VDC LOAD CABLE REPLACEMENT (CONT) (3) Position terminal lug TL167 (4) on terminal block terminal (5) with washer (6) lockwasher (7) and nut (8). (4) Tighten nut (8) to 15-19 lb-ft (21-25 N·m). (5) Install dust boot (9) on 200 amp terminal block to reverse polarity relay 24 vdc load cable (2). (6) Position terminal lug TL168 (10) on reverse polarity relay 24 VDC LOAD terminal (11) with lockwasher (12) and nut (13). (7) Tighten nut (13) to 27-33 lb-ft (37-45 N·m). (8) Position dust boot (9) on terminal lug TL168 (10). 20-292