TM-9-2320-366-20-5 MTV Unit Maintenance Manual M1083 Series - Volume 5 Download
Page 491 of 1158
TM 9-2320-366-20-5 (9) Lift dust boot (16) on terminal lug TL168 (17). (10) Remove nut (18), lockwasher (19), and terminal lug TL168 (17) from reverse polarity relay 24V BAT terminal (20). Discard lockwasher. (11) Lift dust boot (21) on terminal lug TL169 (22). (12) Remove nut (23), lockwasher (24), and terminal lug TL169 (22) from reverse polarity relay 24V LOAD terminal (25). Discard lockwasher. NOTE Note orientation of reverse polarity relay prior to removal. (13) Remove two self-locking nuts (26), screws (27), and reverse polarity relay (28) from brackets (29 and 30). Discard self-locking nuts. d. Installation (M1093/M1094). (1) Position reverse polarity relay (1) on brackets (2 and 3) with two screws (4) and self-locking nuts (5). (2) Tighten two self-locking nuts (5) to 22-27 lb-ft (31-37 N·m). 20-275