TM 9-2320-366-20-5 (33) Lift dust boot (16) on terminal lug TL168 (17). (34) Remove nut (18), lockwasher (19), and terminal lug TL168 (17) from reverse polarity relay 24V BAT terminal (20). Discard lockwasher. (35) Lift dust boot (21) on terminal lug TL169 (22). (36) Remove nut (23), lockwasher (24), and terminal lug TL169 (22) from reverse polarity relay 24V LOAD terminal (25). Discard lockwasher. (37) Position lockwashers (19 and 24) and nuts (18 and 23) on reverse polarity relay 24V BAT terminal (20) and 24V LOAD terminal (25). (38) Remove dust cap (41) from connector J106 (42). (39) Remove nut (43), dust cap lanyard (44), and connector J106 (42) from chemical detection unit mounting bracket (45). (40) Disconnect air filter restriction gauge hose (46) from air flow sensor (47). (41) Loosen clamp (48) on particle extraction hose (49). (42) Disconnect particle extraction hose (49) from adapter (50). (43) Remove particle extraction hose (49) from bracket (51). 20-251