TM-9-2320-366-20-5 MTV Unit Maintenance Manual M1083 Series - Volume 5 Download

Page 466 of 1158

TM 9-2320-366-20-5 20-44. 200 AMP ALTERNATOR KIT REMOVAL (CONT) (22) Remove screw (37) and lockwasher (38) from bracket (29). Discard lockwasher. (23) Remove self-locking nut (39), screw (40), and bracket (29) from spare tire retainer (35). Discard self-locking nut. (24) Position screw (40) and self-locking nut (39) in spare tire retainer (35). (25) Tighten self-locking nut (39) to 43-51 lb-ft (58-69 N·m). (26) Position lockwasher (38) and screw (37) in front lifting beam (41). (27) Tighten screw (37) to 43-51 lb-ft (58-69 N·m). NOTE • Perform steps (28) through (56) on all models except M1093/M1094. • Remove plastic cable ties as required. (28) Lift dust boot (6) on terminal lug TL173 (7). (29) Remove nut (8), lockwasher (9), and terminal lug TL173 (7) from reverse polarity relay 12V BAT terminal (10). Discard lockwasher. (30) Lift dust boot (11) on terminal lug TL174 (12). (31) Remove nut (13), lockwasher (14), and terminal lug TL174 (12) from reverse polarity relay 12V LOAD terminal (15). Discard lockwasher. (32) Position lockwashers (9 and 14) and nuts (8 and 13) on reverse polarity relay 12V BAT terminal (10) and 12V LOAD terminal (15). 20-250