TM-9-2320-366-20-5 MTV Unit Maintenance Manual M1083 Series - Volume 5 Download

Page 464 of 1158

TM 9-2320-366-20-5 20-44. 200 AMP ALTERNATOR KIT REMOVAL (CONT) NOTE • Perform steps (5) through (27) on M1093/M1094. • Remove plastic cable ties as required. (5) Lift dust boot (6) on terminal lug TL173 (7). (6) Remove nut (8), lockwasher (9), and terminal lug TL173 (7) from reverse polarity relay 12V BAT terminal (10). Discard lockwasher. (7) Lift dust boot (11) on terminal lug TL174 (12). (8) Remove nut (13), lockwasher (14), and terminal lug TL174 (12) from reverse polarity relay 12V LOAD terminal (15). Discard lockwasher. (9) Position lockwashers (9 and 14) and nuts (8 and 13) on reverse polarity relay 12V BAT terminal (10) and 12V LOAD terminal (15). (10) Lift dust boot (16) on terminal lug TL168 (17). (11) Remove nut (18), lockwasher (19), and terminal lug TL168 (17) from reverse polarity relay 24V BAT terminal (20). Discard lockwasher. (12) Lift dust boot (21) on terminal lug TL169 (22). (13) Remove nut (23), lockwasher (24), and terminal lug TL169 (22) from reverse polarity relay 24V LOAD terminal (25). Discard lockwasher. (14) Position lockwashers (19 and 24) and nuts (18 and 23) on reverse polarity relay 24V BAT terminal (20) and 24V LOAD terminal (25). 20-248