TM 9-2320-366-20-5 20-43. 200 AMP ALTERNATOR KIT INSTALLATION (CONT) (4) Remove terminal lug TL6 (6) from dust boot (7). NOTE Retain 24 vdc and 12 vdc cable assemblies for future installation. (5) Remove three screws (8), washers (9), clamps (10), 24 vdc cable (11), and 12 vdc cable (12) from air inlet manifold (13). (6) Remove three clamps (10) from 24 vdc cable (11) and 12 vdc cable (12). (7) Remove self-locking nut (14) and washer (15) from alternator (16). CAUTION Ensure pulley does not contact wires, terminal lugs, or terminal screws on front of alternator. Failure to comply may result in damage to equipment. (8) Position pulley (17) on alternator (16) with washer (15) and self-locking nut (14). (9) Position pulley (17) in vise. (10) Tighten self-locking nut (14) to 106-130 lb-ft (144-176 N·m). (11) Remove pulley (17) from vise. 20-228 Change 1