TM-9-2320-366-20-5 MTV Unit Maintenance Manual M1083 Series - Volume 5 Download

Page 436 of 1158

TM 9-2320-366-20-5 19-120 Change 2 19-22. M1090/M1094 FOUR-WAY RELIEF VALVE SOLENOID REPLACEMENT (CONT) (6) Position drain pan under four-way relief valve (4). (7) Remove four screws (7) and solenoid valve (8) from four-way relief valve (4). (8) Remove four preformed packings (9) from four- way relief valve (4). Discard preformed packings. b. Installation. (1) Install four preformed packings (1) on four-way relief valve (2). (2) Position solenoid valve (3) on four-way relief valve (2) with four screws (4). (3) Tighten four screws (4) to 45-55 lb-in. (5-6 N m). (4) Install gasket (5) on connector L9 (6). (5) Connect connector L9 (6) to four-way relief valve (2).