TM-9-2320-366-20-5 MTV Unit Maintenance Manual M1083 Series - Volume 5 Download
Page 426 of 1158
TM 9-2320-366-20-5 19-20. M1089 HYDRAULIC TANK AND MANIFOLD ASSEMBLY REPAIR (CONT) WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (15) Apply antiseize compound to threads of the hydraulic tank nipple (30). (16) Install 90-degree fitting (31) on hydraulic tank (18). (17) Apply antiseize compound to threads of adapter fitting (32). (18) Install adapter fitting (32) on 90-degree fitting (31). (19) Apply antiseize compound to threads of manifold (33). (20) Install manifold (33) on hydraulic tank (18) with matchmarks aligned. (21) Apply antiseize compound to threads of magnetic plug (34). (22) Install magnetic plug (34) in hydraulic tank (18). 19-110