TM 9-2320-366-20-5 WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (10) Apply antiseize compound to two 45-degree fittings (6). (11) Install two 45-degree fittings (6) on manifold (5). (12) Apply antiseize compound to threads of 45-degree fitting (2). (13) Install 45-degree fitting (2) and 90-degree fitting (1) on manifold (5) with matchmarks aligned. f. Hydraulic Tank Assembly. CAUTION Metal side of cushion must be against resilient mount. Failure to comply may result in damage to equipment. (1) Position two cushions (1) and resilient mounts (2) on front brackets (3) with eight screws (4), spacers (5), and self-locking nuts (6). (2) Tighten eight self-locking nuts (6) to 144-192 lb-in. (16- 22 N·m). 19-107