TM-9-2320-366-20-5 MTV Unit Maintenance Manual M1083 Series - Volume 5 Download
Page 422 of 1158
TM 9-2320-366-20-5 19-20. M1089 HYDRAULIC TANK AND MANIFOLD ASSEMBLY REPAIR (CONT) (4) Position 90-degree fitting (3) in vise. WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (5) Apply antiseize compound to threads of valve (4). (6) Install valve (4) on 90-degree fitting (3) with matchmarks aligned. (7) Position manifold (5) in vise. (8) Apply antiseize compound to threads of manifold (5). (9) Install manifold (5) on valve (4) with matchmarks aligned. 19-106