TM-9-2320-366-20-5 MTV Unit Maintenance Manual M1083 Series - Volume 5 Download

Page 411 of 1158

TM 9-2320-366-20-5 Change 2 19-95 19-19. HYDRAULIC RESERVOIR AND BRACKET REPLACEMENT (CONT) (14) Apply sealing compound to threads of nut (20). (15) Position nut (20) on strap (12). (16) Tighten nut (20) to 42-52 ft-lb (57-71 N•m). (17) Connect hose (21) to fitting (19). (18) Connect hose (22) to 90-degree fitting (16). (19) Position guard support bracket (23) on bracket (1) with two bolts (24) and self-locking nuts (25). (20) Position two bolts (24) and self locking nuts (25) in guard support bracket (23) and stone guard (26). (21) Tighten four self-locking nuts (25) to 20-24 lb-ft (27- 33 N•m). e. Follow-On Maintenance. (1) Install hydraulic oil filter assembly (para 19-13). (2) Fill hydraulic reservoir (Appendix H). End of Task. WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, washer immediately with soap and water. Failure to comply may result in injury to personnel. NOTE Perform steps (19) through (21) on models M1090 and M1094.