TM-9-2320-366-20-5 MTV Unit Maintenance Manual M1083 Series - Volume 5 Download
Page 334 of 1158
TM 9-2320-366-20-5  19-5. HYDRAULIC MANIFOLD FILTER REPLACEMENT  This task covers:  a. Removal  b. Installation  c. Follow-On Maintenance  INITIAL SETUP  Equipment Conditions  Engine shut down (TM 9-2320-366-10-1).  Tools and Special Tools  Tool Kit, Genl Mech (Item 46, Appendix C)  Gloves, Rubber (Item 13, Appendix C)  Goggles, Industrial (Item 15, Appendix C)  Materials/Parts  Hydraulic Fluid A (Item 25, Appendix D)  Filter Assembly (2) (Item 14, Appendix G)  a. Removal.  WARNING  Hydraulic fluid (MIL-L-5606) is TOXIC.  Wear protective goggles and gloves; use  only in well ventilated area; avoid contact  with skin, eyes, and clothes. Skin and  clothing that come in contact with  hydraulic oil should be washed  immediately. Saturated clothing should  be removed immediately. Failure to  comply may result in injury to personnel.  (1) Remove two plugs (1) from hydraulic manifold (2).  (2) Remove two preformed packings (3) from plugs (1).  Discard preformed packings and plugs.  (3) Remove two retainers (4), filters (5), and springs (6) from  hydraulic manifold (2). Discard retainers, filters, and  springs.  19-22