TM-9-2320-366-20-5 MTV Unit Maintenance Manual M1083 Series - Volume 5 Download
Page 305 of 1158
TM 9-2320-366-20-5 e. Air/Hydraulic Power Unit Installation. (1) Position air/hydraulic power unit (1) on air/hydraulic unit mounting bracket (2) with four washers (3), spring washers (4), and screws (5). (2) Tighten four screws (5) to 18-22 lb-ft (24-30 N·m). (3) Install two preformed packings (6) on fittings (7). (4) Install two fittings (7) in air/hydraulic power unit (1). (5) Connect two hydraulic hoses (8) to fittings (7). WARNING Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (6) Apply antiseize compound to threads of fitting (9). (7) Install fitting (9) in air/hydraulic power unit (1). (8) Connect air hose (10) to fitting (9). Change 1 19-8.9