TM 9-2320-366-20-5 17-162 Change 2 17-32. 30K WINCH VALVE MANIFOLD ASSEMBLY REPLACEMENT/REPAIR (CONT) e. Installation. (1) Position valve manifold assembly (1) on 30K winch assembly (2) with two screws (3), washers (4), and self-locking nuts (5). (2) Tighten two self-locking nuts (5) to 12-24 lb-in. (1-3 N•m). (3) Install ten hoses (6) on fittings (7). (4) Position hose (8) on fitting (9). (5) Tighten hose (8) approximately 2 1/2 turns past hand tight. (6) Connect thirteen ground leads (10) to terminal block (11) terminal lugs C. (7) Connect electrical lead (12) to terminal block (11) terminal lug 13. (8) Connect electrical lead (13) to terminal block (11) terminal lug 6. (9) Connect electrical lead (14) to terminal block (11) terminal lug 3. (10) Connect electrical lead (15) to terminal block (11) terminal lug 16. (11) Connect electrical lead (16) to terminal block (11) terminal lug 4. NOTE Apply antiseizing tape to first two to five threads of fittings prior to installation of hoses. NOTE Positive electrical leads are yellow. Ground electrical leads are black.