TM 9-2320-366-20-5 Change 2 17-161 d. Assembly. (1) Position rectifier (1) on electrical leads (2). (2) Solder rectifier (1) to electrical leads (2). (3) Install insulation sleeving (3) over electrical leads (2) and shrink insulation sleeving. NOTE (3.1) Apply sealant to threads of plug (4) fittings (6) And fittings (7) (4) Install plug (4) in valve manifold assembly (5). (5) Install fitting (6) in valve manifold assembly (5). (6) Install ten fittings (7) in valve manifold assembly (5). (6.1) Tighten plug (4) fitting (6) and fittings (7) 2-3 turns with wrench. WARNING NOTE Cathode side of rectifier (side with band) is positioned toward positive lead (yellow) and the opposite end positioned toward negative ground lead (black). Apply sealant to first two to five threads of fittings and plugs prior to installation. Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and sue well-ventilated area. If adhesive, solvent, or anti-seize compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel.