TM 9-2320-366-20-5 Change 2 17-155 (7) Position hydraulic hoses (8 and 9) on 90-degree fittings (6). (8) Tighten hoses (8 and 9) to 18-20 lb-ft (24-27 N m). (9) Install inner tube (10) in folding boom frame (2). (10) Install retaining pin (12) on inner tube (10). (11) Install two retaining rings (13) on retaining pin (12). WARNING Use care when installing retaining rings. Retaining rings are under tension and can act as projectiles when released. Failure to comply may result in injury to personnel.