TM-9-2320-366-20-5 MTV Unit Maintenance Manual M1083 Series - Volume 5 Download
Page 195 of 1158
TM 9-2320-366-20-5 (3) Connect M1089 30K winch test adapter on 90-degree fitting (2). (4) Install STE/ICE-R 0-1000 PSI pressure transducer in M1089 30K winch test adapter. (5) Connect hose (1) to M1089 30K winch test adapter. (6) Start engine (TM 9-2320-366-10-1). (7) Perform STE/ICE-R test #50. (8) Turn knob (3) on regulating valve (4) clockwise until pressure reads 65 psi on STE/ICE-R. (9) Push in knob (3) on regulating valve (4). (10) Shut down engine (TM 9-2320-366-10-1). (11) Remove STE/ICE-R 0-1000 PSI transducer from M1089 30K winch test adapter. (12) Disconnect hose (1) from M1089 30K winch test adapter. (13) Disconnect M1089 30K winch test adapter from 90- degree fitting (2). Change 1 17-149