TM 9-2320-366-20-5 Change 2 17-147 d. Assembly. (1) Apply sealing compound to threads of two plugs (1), fitting (2), 90-degree fittings (3 and 4), and pipe nipple (5). (2) Install two plugs (1) in regulating valve (6). (3) Install pipe nipple (5), fitting (2), and 90-degree fitting (3) in shuttle valve (7). (4) Install regulating valve (6) on pipe nipple (5). (5) Install 90-degree fitting (4) in regulating valve (6). WARNING NOTE • Install fittings in the same orientation as noted during removal. • Install fittings, plugs, and pipe nipple in steps (2) through (5) finger tight, then wrench tighten an additional 2-3 turns. Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel.