TM-9-2320-366-20-5 MTV Unit Maintenance Manual M1083 Series - Volume 5 Download

Page 193 of 1158

TM 9-2320-366-20-5 Change 2 17-147 d. Assembly. (1) Apply sealing compound to threads of two plugs (1), fitting (2), 90-degree fittings (3 and 4), and pipe nipple (5). (2) Install two plugs (1) in regulating valve (6). (3) Install pipe nipple (5), fitting (2), and 90-degree fitting (3) in shuttle valve (7). (4) Install regulating valve (6) on pipe nipple (5). (5) Install 90-degree fitting (4) in regulating valve (6). WARNING NOTE Install fittings in the same orientation as noted during removal. Install fittings, plugs, and pipe nipple in steps (2) through (5) finger tight, then wrench tighten an additional 2-3 turns. Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel.