TM-9-2320-366-20-5 MTV Unit Maintenance Manual M1083 Series - Volume 5 Download

Page 192 of 1158

TM 9-2320-366-20-5 17-30. M1089 30K WINCH TENSIONER PNEUMATIC VALVE ASSEMBLY REPLACEMENT/REPAIR/ADJUSTMENT (CONT) c. Cleaning/Inspection. WARNING Dry Cleaning Solvent (P-D-680) is TOXIC and flammable. Wear protective goggles and gloves; use only in well ventilated area; avoid contact with skin, eyes, and clothes, and do not breathe vapors. Keep away from heat or flame. Never smoke when using solvent; the flashpoint for Type I Dry Cleaning Solvent is 100°F (38°C) and for Type II is 130°F (50°C). Failure to comply may result in serious injury or death to personnel. If personnel become dizzy while using cleaning solvent, immediately get fresh air and medical help. If dry cleaning solvent contacts skin or clothes, flush with cold water. If dry cleaning solvent contacts eyes, immediately flush eyes with water and get immediate medical attention. Failure to comply may result in injury to personnel. (1) Clean all metal parts with dry cleaning solvent. NOTE Replace any part that fails visual inspection. (2) Check two 90-degree fittings (1) and fitting (2) for corrosion, pitting, cracks, damaged or worn threads, and obstructions. (3) Check pipe nipple (3) for corrosion, pitting, cracks, damaged or worn threads, and obstruction to ports. (4) Check two ports (4) in regulating valve (5) for obstruction of passages. (5) Check two ports (6) in shuttle valve (7) for obstruction of passages. (6) Check two plugs (8) for corrosion, pitting, cracks, or damaged or worn threads. 17-146 Change 1