TM-9-2320-366-20-5 MTV Unit Maintenance Manual M1083 Series - Volume 5 Download
Page 125 of 1158
TM 9-2320-366-20-5 (4) Remove 90 degree fitting (2) from air chamber (8). b. Installation. WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (1) Apply antiseize compound to threads of 90-degree fitting (1). (2) Position 90-degree fitting (1) in air chamber (2). (3) Tighten 90-degree fitting (1) approximately 2 1/2 turns past hand tight. 17-83