TM-9-2320-366-20-5 MTV Unit Maintenance Manual M1083 Series - Volume 5 Download

Page 124 of 1158

TM 9-2320-366-20-5 17-19. M1089 30K WINCH CABLE TENSIONER AIR CHAMBER REPLACEMENT This task covers: a. Removal b. Installation c. Adjustment d. Follow-On Maintenance INITIAL SETUP Equipment Conditions Air tanks drained (TM 9-2320-366-10-1). Tools and Special Tools Tool Kit, Genl Mech (Item 46, Appendix C) Wrench, Torque, 0-175 lb-ft (Item 58, Appendix C) STE/ICE-R (Item 41, Appendix C) Tools and Special Tools (Cont) Wrench, Torque, 0-75 lb-in. (Item 90, Appendix B) Materials/Parts Lockwasher (2) (Item 97, Appendix G) Nut, Self-Locking (Item 136, Appendix G) a. Removal. NOTE Left and right 30K winch cable tensioners air chambers are removed the same way. Left side shown. (1) Disconnect air hose (1) from 90 degree fitting (2). (2) Remove self-locking nut (3) and screw (4) from tensioner arm (5). Discard self-locking nut. (3) Remove two nuts (6), lockwashers (7), and air chamber (8) from winch tensioner support (9). Discard lockwashers. 17-82