TM 9-2320-366-20-4 d. Installation. WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (1) Apply antiseize compound to threads of three 90-degree fittings (1). CAUTION Do not overtighten fittings. Failure to comply may result in damage to equipment. (2) Install three 90-degree fittings (1) in manifold valve assembly (2). (3) Install bracket (3) on manifold valve assembly (2) with four washers (4) and screws (5). (4) Position manifold valve assembly (2) on cab (6) with four screws (7). (5) Tighten four screws (7) to 120 lb-in. (14 N m). NOTE Install plastic cable ties as required. (6) Install three air hoses (8) on 90-degree fittings (1). (7) Connect connector P112 (9) to manifold valve assembly (2). (8) Connect connector P113 (10) to manifold valve assembly (2). Change 1 12-17