TM 9-2320-366-20-4  11-29. PRESSURE PROTECTION VALVE REPLACEMENT (CONT)  WARNING  Adhesives, solvents, and sealing com-  pounds can burn easily, can give off  harmful vapors, and are harmful to skin  and clothing. Keep away from open fire  and use in a well-ventilated area. If  adhesive, solvent, or sealing compound  gets on skin or clothing, wash  immediately with soap and water. Failure  to comply may result in injury to  personnel.  (11) Apply antiseize compound to threads of 45-degree fitting  (7).  (12) Install 45-degree fitting (7) in tee fitting (4).  (13) Apply antiseize compound to threads of fitting (8).  (14) Install fitting (8) in tee fitting (4).  (15) Apply antiseize compound to threads of 90-degree fitting  (9).  (16) Install 90-degree fitting (9) in air tank (10).  (17) Install pressure protection valve (2) in 90-degree fitting  (9).  (18) Rotate pressure protection valve (2) to horizontal  position.  11-180