TM-9-2320-366-20-4 MTV Unit Maintenance Manual M1083 Series - Volume 4 Download

Page 785 of 1558

TM 9-2320-366-20-4 (14) Remove 90-degree fitting (4) from two-way check valve (18). (15) Remove 90-degree fitting (16) from two-way check valve (18). (16) Remove inversion valve (19) from reducer fitting (20). (17) Remove reducer fitting (20) from two-way check valve (18). (18) Remove 90-degree fittings (9 and 11) from inversion valve (19). d. Secondary Air Tank Installation (M1088/M1089). WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (1) Apply antiseize compound to threads of 90-degree fittings (1 and 2), threads on both sides of reducer fitting (3), 90-degree fitting (4), and 90-degree fitting (5). (2) Install 90-degree fittings (1 and 2) in inversion valve (6). (3) Install reducer fitting (3) in two-way check valve (7). (4) Install inversion valve (6) on reducer fitting (3). (5) Install 90-degree fitting (4) in two-way check valve (7). (6) Install 90-degree fitting (5) in two-way check valve (7). 11-143