TM-9-2320-366-20-4 MTV Unit Maintenance Manual M1083 Series - Volume 4 Download
Page 744 of 1558
TM 9-2320-366-20-4 11-110 Change 2 11-19. PARK CONTROL TWO-WAY CHECK VALVE REPLACEMENT (CONT) (7) Apply antiseize compound to threads of two adapters (5). (8) Install two air pressure transmitters (1) with adapters (2) in tee fittings (4). (9) Position park control two-way check valve (6) on bracket (7) with screw (8), washer (9), and self- locking nut (10). (10) Tighten self-locking nut (9) to 13-16 lb-ft (18-22 N• m). WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel.