TM-9-2320-366-20-4 MTV Unit Maintenance Manual M1083 Series - Volume 4 Download

Page 743 of 1558

TM 9-2320-366-20-4 Change 2 11-109 b. Installation. (1) Apply adhesive compound to bottom threads of two air pressure transmitters (1) (2) Install two adapters (2) on air pressure Transmitters (1). (3) Apply antiseize compound to threads of 90-degree fitting (3) two tee fittings (4), and 90-degree fittings (5). (4) Install 90-degree fitting (3) in park control two-way check valve (6). (5) Install two tee fittings (4) in park control two-way check valve (6). (6) Install two 90-degree fittings (5) in tee fittings (4). WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel.