TM 9-2320-366-20-4 b. Installation. WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (1) Apply sealing compound to threads of 45-degree fitting (1), 90-degree fitting (2), and fitting (3). (2) Install 45-degree fitting (1) in quick release valve (4). (3) Install 90-degree fitting (2) in quick release valve (4). (4) Install fitting (3) in quick release valve (4). (5) Position quick release valve (4) on bracket (5) with two washers (6), screws (7), washers (8), and self-locking nuts (9). (6) Tighten two self-locking nuts (9) to 14-18 lb-ft (20-24 N·m). 11-95