TM-9-2320-366-20-4 MTV Unit Maintenance Manual M1083 Series - Volume 4 Download

Page 723 of 1558

TM 9-2320-366-20-4 NOTE Note orientation of fittings prior to removal. (3) Remove three 90-degree fittings (2) from two-way check valve (7). b. Installation. WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (1) Apply antiseize compound to threads of three 90-degree fittings (1). (2) Install three 90-degree fittings (1) in two-way check valve (2). 11-91