TM-9-2320-366-20-4 MTV Unit Maintenance Manual M1083 Series - Volume 4 Download
Page 719 of 1558
TM 9-2320-366-20-4 (8) Remove two self-locking nuts (10), screws (11), washers (12), and booster valve (6) from bracket (13). Discard self-locking nuts. b. Installation. (1) Position booster valve (1) on bracket (2) with two washers (3), screws (4), and self-locking nuts (5). (2) Tighten two self-locking nuts (5) to 14-18 lb-ft (20-24 N·m). WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (3) Apply antiseize compound to threads of plug (6). (4) Install plug (6) in booster valve (1). 11-87