TM 9-2320-366-20-4 NOTE Perform steps (6.1) through (6.2) on M1089. (6.1) Apply antiseize compound to threads of two 90-degree fittings (2), 90-degree fitting (3), fitting (4), 45-degree fitting (5) and two 45-degree fittings (5.1). (6.2) Install two 90-degree fittings (2) in relay valve (6). (6.3) Install 90-degree fitting (3) in relay valve (6). (6.4) Install fitting (4) in relay valve (6). (6.5) Install 45-degree fitting (5) in relay valve (6). (6.6) Install two 45-degree fittings (5.1) in relay valve (6). (7) Position relay valve (6) on panel (7) with two washers (8), screws (9), and self-locking nuts (11). (8) Tighten two self-locking nuts (11) to 14-18 lb-ft (20-24 N·m). (9) Connect air hose (12) to 45-degree fitting (5). (10) Connect air hose (13) to 90-degree fitting (3). Change 1 11-83