TM-9-2320-366-20-4 MTV Unit Maintenance Manual M1083 Series - Volume 4 Download
Page 702 of 1558
TM 9-2320-366-20-4 11-11. LOAD AVERAGING CHANNEL REPLACEMENT (CONT) WARNING Adhesive Sealant MIL-S-46163 can damage your eyes. Wear safety goggles/glasses when using; avoid contact with eyes. If sealant contacts eyes, flush eyes with water and get immediate medical attention. Failure to comply may result in injury to personnel. (3) Apply adhesive to threads of two screws (6). (4) Position load averaging channel (7) on two load averaging channel mounting springs (2) with screws (6). (5) Tighten two screws (1 and 6) to 25-31 lb-ft (34-42 N·m). (6) Apply adhesive to threads of screw (8). (7) Position load sensing valve control cable (9) on load averaging channel (7) with screw (8). (8) Tighten screw (8) to 25-31 lb-ft (34-42 N·m). c. Follow-On Maintenance. Perform load sensing valve adjustment (para 11-10). End of Task. 11-72 Change 1