TM-9-2320-366-20-4 MTV Unit Maintenance Manual M1083 Series - Volume 4 Download

Page 695 of 1558

TM 9-2320-366-20-4 CAUTION Load sensing valve control cable must be installed in cable clamp on back side of control lever, opposite cable clamp screw. Failure to comply may result in damage to load sensing valve control cable. (17) Install load sensing valve control cable (17) in cable clamp (18). (18) Perform load sensing valve adjustment. e. Load Sensing Valve Adjustment. WARNING Proper adjustment of load sensing valve may only be accomplished with vehicle unloaded. Failure to comply may result in injury to personnel or damage to equipment. (1) Position cable clamp (1) on control lever (2) in accordance with Table 11-1. Load Sensing Valve Cable Clamp Dimensions. NOTE Dimensions in Table 11-1. Load Sensing Valve Cable Clamp Dimensions are measured from center of pivot shaft to center of cable clamp. Table 11-1. Load Sensing Valve Cable Clamp Dimensions Model Number Dimension M1083, M1089, M1093, M1092 6-13/16 - 7-1/16 in. (173-179 mm) M1084, M1086 5-7/8 - 6-1/8 in. (149-155 mm) M1085, M1088, M1090, M1094, M1096 6-1/2 - 6-3/4 in. (165-171 mm) Change 1 11-65