TM 9-2320-366-20-4 11-10. LOAD SENSING VALVE AND CONTROL CABLE REPLACEMENT/ADJUSTMENT (CONT) d. Load Sensing Valve Installation. WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (1) Apply antiseize compound to threads of 45-degree fitting (1). (2) Install 45-degree fitting (1) in load sensing valve (2). (3) Deleted. NOTE Perform steps (4) and (5) on all models except M1088 and M1089. (4) Apply antiseize compound to threads of tee fitting (3). (5) Install tee fitting (3) in load sensing valve (2). (6) Deleted. NOTE Perform steps (7) and (8) on M1088 and M1089. (7) Apply antiseize compound to threads of 45-degree fitting (4). (8) Install 45-degree fitting (4) in load sensing valve (2). (9) Deleted. 11-62 Change 1