TM-9-2320-366-20-4 MTV Unit Maintenance Manual M1083 Series - Volume 4 Download

Page 628 of 1558

TM 9-2320-366-20-4 10-28 Change 2 10-6. SPINDLE REPLACEMENT (CONT) (4) Apply antiseize compound to threads of three fittings (8, 9, and 10). (5) Install fittings (9 and 10) to spindle (5). (6) Install fitting (8) on fitting (10). (7) Apply antiseize compound to threads of 45-degree fitting (11). (8) Install 45 degree fitting (11) in spindle (5). WARNING Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. To avoid injury or death, keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. NOTE Steps (4) through (6) apply to front spindles only. NOTE Steps (7) and (8) apply to intermediate and rear spindles only.