TM 9-2320-366-20-4 7-746 Change 2 7-146 DUMP SWITCH BRACKET AND JUMPER CABLE REPLACEMENT (CONT) b. Installation. (1) Route auxiliary panel jumper cable assembly (1) in auxiliary panel housing (2). (2) Connect connector P925 (3) to connector J925 (4). (3) Position auxiliary panel (5) on auxiliary panel housing (2) with six screws (6). (4) Tighten six screws (6) to 18 lb-in. (2 Nm).