TM-9-2320-366-20-4 MTV Unit Maintenance Manual M1083 Series - Volume 4 Download
Page 382 of 1558
TM 9-2320-366-20-4 7-143. M1084/M1086 JUNCTION BOX MODIFICATION (CONT) (32) Route blue wire (36) to terminal block (7). (33) Cut blue wire (36) to length. (34) Install connector (37) on blue wire (36). (35) Connect blue wire (36) on terminal block (7) position 9 with screw (38). (36) Route black wire (39) to terminal block (7). (37) Cut black wire (39) to length. (38) Install connector (40) on black wire (39). (39) Connect black wire (39) on terminal block (7) position 7 with screw (41). NOTE • Perform steps (40) through (59) on shutdown relay. • Relay socket wires must be trimmed to length according to nearest routing in junction box. (40) Route green wire (42) to ground strip (5). (41) Cut green wire (42) to length. (42) Install quick disconnect terminal (43) on green wire (42). (43) Connect green wire (42) on ground strip (5) position 19. 7-712 Change 1