TM-9-2320-366-20-4 MTV Unit Maintenance Manual M1083 Series - Volume 4 Download
Page 381 of 1558
TM 9-2320-366-20-4 NOTE • Perform steps (20) through (39) on lockout relay. • Relay socket wires must be trimmed to length according to nearest routing in junction box. (20) Route green wire (28) to ground strip (5). (21) Cut green wire (28) to length. (22) Install quick disconnect terminal (29) on green wire (28). (23) Connect green wire (28) on ground strip (5) position 20. (24) Route white wire (30) to terminal block (7). (25) Cut white wire (30) to length. (26) Install connector (31) on white wire (30). (27) Connect white wire (30) on terminal block (7) position 8 with screw (32). (28) Route red wire (33) to terminal block (7). (29) Cut red wire (33) to length. (30) Install connector (34) on red wire (33). (31) Connect red wire (33) on terminal block (7) position 10 with screw (35). Change 1 7-711